ISM2000

4 DIGIT (10000 COUNTS) PROGRAMMABLE MULTIMETER
ism2000
Description

45mm high LED Display

Voltage Current Resistance Frequency
dB
True RMS
pH temperature
Diode test
Offset
Autoranging
RS 232 or USB Programmable
include PC_DMM Software for
Windows®

Specifications

DC Voltage
Ranges : 1, 10, 100, 1000V
Accuracy : ±(0,1 % + 1 digit)
Input Impedance: 10MΩ
Input Protection : ±1100V
AC Voltage
Ranges : 1, 10, 100, 500V
Accuracy (TRMS) :
1, 10V : ± (0,2% + 3 digits) 40Hz - 3kHz and DC
± (1% + 3 digits) 20Hz - 40Hz and 3kHz - 20kHz
± (5% + 3 digits) 20kHz - 100kHz
100V, 500V : ± (0,2% + 3 digits) 40Hz - 1kHz and DC
± (1% + 3 digits) 20Hz - 40Hz and 1kHz - 3kHz
Input Impedance: 1MΩ // 100pF
Input Protection : 750V crest
dBV display: from 40.00 to +54.00dBV
0 dBV = 1V
Accuracy: same as value expressed in Voltage
Current
Ranges : 10mA, 1A, 20A
Protection : 10mA et 1A by fuse
Accuracy (DC) : ±(0,2% + 2 digits)
(AC) : ±(0,5% + 3 digits) 40Hz - 3kHz and DC
± (1% + 3 Digits) 20Hz - 40Hz and 400Hz - 3kHz

Diode test
Current 400μA Voltage 0 to 10V


Resistance
Ranges : 1, 10, 100kΩ, 10, 50MΩ
Accuracy : 1kΩ to 10MΩ : ±(0,1 % + 2 digits)
50MΩ : ±(0,5 % + 5 digits)
Input Protection : 380Vrms max.

Frequency
Autoranging. Measures Voltage or current
Frequency range : 5Hz to 400kHz
Resolution : 4 digits from 5Hz to 400kHz
Accuracy: ± 1 digit

pH
Range : 0 to 14 units pH
Automatic or Manual Compensation of measurement
depending on temperature from 0 °C to 100 °C
Combinated Electrode with BNC output
Input Impedance : >Ω 10 13
Resolution : ± 0,01 digit
Accuracy : ± 0,01 digit

Temperature
Probe: Thermocouple type K,miniature plug
Display in °C
Temperature range Type K (without probe) : -200 to +
1250 °C
Resolution : - 100 °C to +100 °C : 0,1 °C
- 200 to -100 °C and 100 to 1200 °C : 1°C
Accuracy (without probe) :
± (0,1% +0,5°C) from -100 to +100 °C
± (0,1% + 1,5°C) beyond


Security:
CEI 1010-1 Cat III 600V,Cat II 1000V
Interface :
RS232 (3 wires). Xon-Xoff Protocol.
Baud rate : 1200/9600 Bauds
All functions and ranges programmable.
Power :
230 V 50-60Hz, max. 12W
Dimensions :
240 x 240 x 140 mm (L xl x P)
Weight :
about 2 kg
Misc :
4 Digit 45mm high LED Display plus sign on the front and 13mm Display plus sign on the rear.
Beeper indicates overload

 